They differ considerably from the conventional gabled roofs in shape and construction.
Zinc pitched roof detail.
Refer to the rain carrying table in this booklet for the maximum allowable panel length per slope that will provide adequate drainage.
For over 45 years berridge manufacturing co.
Has worked to set the standard by designing developing and manufacturing superior architectural metal products and portable roll forming technology.
Rheinzink double lock standing seam roofing the double lock standing seam is a further development of the original hollow seam or the simple standing seam.
The minimum slope for zinc roofs is 3º as built.
While the gabled roof is always pitched in two directions the mono pitch always slants in a single direction.
For longer slopes and lower roof pitches contact fabral for other suitable profiles.
This air space must be a vented space with openings.
First mentioned in relevant literature in 1899 it is the preferred choice over other systems for roof pitches starting at approx.
Roof pitch the metal roofing panels shown in this manual require a min imum slope of 2 ʺ per foot to ensure proper drainage.
Our products are tested proven and covered with full technical support and warranties.
Warm zinc roof construction can also use timber substrates but the need to reduce cold bridging in many countries has led to the use of rigid insulation boards and composite insulation boards or sandwich panels as the direct substrate under the zinc.
For a pitch lower than 14º the joints must be taped between 14º 22 there must be an overlap of 200mm just steeper than 22 or unless it changes above 40º there must be an overlap of 150mm.
We recommend 5 degrees however due to site conditions and execution.
Between the zinc plus and the insulation the vmzinc breather membrane link to 8 1 vmzinc membrane is fixed with an overlap depending on the pitch.
Mono pitched roofs are also known by the names of skillion roofs shed roofs pent roof and lean to roof.
A 5 degree roof pitch means nearly 90mm in every metre which gives you over 250 mm to play with and that extra 10cm is quite a lot on site.
Definition of cold roof in the uk in order to put the cold ventilated roof system into context we will refer to it as a roof where there is a continuous air space of at least 50mm between the substrate supporting the zinc and the insulation.
Sig zinc and copper recommend that the minimum pitch for a standing seam zinc roof is five degrees with an absolute minimum of 3 degrees.